FLASH ECONOMIZER HEAT RECOVERY SYSTEM

Dimensions (Specification Print)


Flash Economizer Hear Recovery Systems

MODEL
A
B
C
D
E
F
G
H
AHR 3
96
44
44 1/2
8
1
2 1/2
1
3/4
AHR 6
110
49
50
10
1 1/2
3
1
3/4
AHR 10
100
44
42
16
1 1/2
4
2
1 1/4
AHR 20
140
67
62
18
1 1/2
6
2
1 1/2
AHR 30
172
76
85
18
1 1/2
6-8
2
1 1/2
AHRB 3-15
97
50
36
10
1
2 1/2
1
1
AHRB 6-30
111
53
46
12
1 1/2
3
1
1 1/4
AHRB 10-50
106
50
44
16
1 1/2
4
2
1 1/2
AHRB 20-100
140
67
62
18
1 1/2
6
2
2
AHRB 30-150
132 1/2
67
52 1/2
24
1 1/2
6-8
3
2 1/2

 

NOZZELL SCHEDULE
E. ContinuousBlowdown Inlet
F. Steam Vent
G. Condensate Drain
H. Cold Water Inlet and Outlet

Dimensions are in inches


Suggested Specifications

Furnish and install as shown on drawings, a Penn Flash Economizer Model NO. (AHR or AHRB)_________________________ as manufactured by the Penn Separator Corp. Brookville PA.

The Flash Economizer shall be capable of handling _____________ #/hr. continuous blowdown and _____________ gpm make-up at a boiler operating pressure/pressures of _____________ psig. flashing to low pressure deaerator, feedwater heater or other low pressure use at _____________ psig.

The Flash Economizer shall consist of the following components and accessories:

1. Vertical Flash Separator section with threaded connections for the tangential inlet with a stainlesss steel wear plate, blowdown drain, recovered steam vent, and tank cleanout connections as well as couplings as required for accessories.

2. Vertical coil-type heat exchanger made of (copper or stainless steel) with steel threaded connections for make-up inlet, outlet, and openings for remote thermometer bulbs.

3. Flanged bottom section with drop out coil design for easy cleaning and maintenance.

4. Balanced float trap with all working parts constructed of stainless steel and removable seats, located externally on the Flash Economizer and back vented to maintain a constant level Ithe tank.

5. Thermometer gauge panel showing temperatures of the make-up inlet, make-up outlet, and blowdown water to drain.

6. A safety relief valve set a t150 psig., a Michigan site level gauge, and tank clean out valve.

7. Optional Accessories shall include a high level alarm switch, multi-boiler manifold, flow control or blowdown valves, pressure gauge, and a sample cooler with piping.

All the above components shall be mounted on a table base with four angle iron floor supports and pads in such a manner that will allow gravity flow of the blowdown water through the system. The finished system shall be painted with a blue enamel exterior.

The Flash Economizer shall be designed and constucted in accordance with the latest ASME Code Sec. VIII, Div.1. requirements for a unfired pressure vessel for 150 psig MAWP.

 

PENN SEPARATOR CORPORATION
5 South Pickering
P.O. BOX 340
Brookville, PA 15825
(814) 849-7328
Fax: (814) 849-4510
TOLL FREE: 1-888-PENN-SEP (7366-737)


Designed by OnTech
OnTech