FLASH SEPARATORS

Sizing, Selection, and Dimensions


Flash Separators

"I"
Inlet
Specify Size to Match Return or Blowdown Line Size
"H"
Height
34" - 56" - 72" - 96" - 108"
"DIA"
Outside
Diameter
6.625" - 8.625" - 10.75" - 14" - 16" - 18" - 20" - 24" - 30" - 36"
"D"
Drain
1" - 1 1/4" - 1 1/2" - 2" - 2 1/2" - 3" - 4" - 5"
"V"
Vent
2" - 2 1/2" - 3" - 4" - 5" - 6" - 8" - 10" - 12" - 14" - 16" - 18"
"PL"
Plate
Thickness
Std. Wt. - 5/16" - 3/8"


Flash Separators are sized for the condensate flow entering the tank and the amount of flash steam that is produced when venting to a lower pressure. To select a flash separator use Chart "A" to determine the flash steam amount and Chart "B" that gives the size of tank and nozzle connections sizes required.

CHART "A" - PERCENTAGE FLASH STEAM


To use Chart A follow the "PRESSURE FROM" (horizontal at the top) down vertically to the "FLASH TO" pressure. All pressures are in psig.


PRESSURE FROM PSIG
F
L
A
S
H

T
O

P
S
I

G
600
500
450
400
350
300
250
200
150
100
75
50
25
500
2.8
400
5.8
3.1
1.3
350
7.5
4.8
3.0
1.8
300
9.2
6.6
4.8
3.6
1.9
250
11.1
8.5
6.8
5.6
3.9
2.1
225
12.2
9.7
8.0
6.8
5.1
3.3
1.2
200
13.3
10.8
9.1
7.9
6.2
4.4
2.4
175
14.4
11.9
10.3
9.1
7.4
5.7
3.7
1.3
150
15.7
13.2
11.6
10.4
8.8
7.0
5.0
2.7
125
17.1
14.6
13.0
11.9
10.3
8.5
6.6
4.3
1.6
100
18.6
16.2
14.6
13.5
11.9
10.2
8.3
6.0
3.4
75
20.3
18.0
16.4
15.3
13.7
12.1
10.2
7.9
5.4
2.0
50
22.6
20.3
18.8
17.7
16.1
14.5
12.6
10.4
7.9
4.6
2.6
25
25.4
23.1
21.6
20.6
19.1
17.5
15.6
13.5
11.0
7.8
5.9
3.3
15
26.9
24.7
23.2
22.1
20.6
19.0
17.2
15.1
12.7
9.5
7.6
5.1
1.8
10
27.8
25.6
24.2
23.1
21.6
20.1
18.3
16.2
13.8
10.6
8.7
6.2
2.9
5
28.9
26.7
25.2
24.2
22.7
21.1
19.4
17.3
14.9
11.8
9.9
7.4
4.2
0
30.2
28.0
26.6
25.6
24.1
22.6
20.8
18.8
16.4
13.3
11.4
9.0
5.8



LBS/HR
Condensate

LBS/HR FLASH STEAM

100
500
700
1000
2000
3000
4000
8000
12000
18000
21000
25000
35000
100,000
HEIGHT
DIA.
DRAIN
VENT
108
30
5
2
108
30
5
2
108
30
5
2 1/2
108
30
5
3
108
30
5
4
108
30
5
5
108
30
5
6
108
30
5
8
108
30
5
10
108
30
5
12
108
30
5
14
108
36
5
16
108
36
4
18

90,000

HEIGHT
DIA.
DRAIN
VENT
96
30
5
2
96
30
5
2
96
30
5
2 1/2
96
30
5
3
96
30
5
4
96
30
5
5
96
30
5
6
96
30
5
8
96
30
5
10
96
30
5
12
96
30
4
14
96
36
4
16
96
36
4
18
80,000
HEIGHT
DIA.
DRAIN
VENT
96
24
5
2
96
24
5
2
96
24
5
2 1/2
96
24
5
3
96
24
5
4
96
24
5
5
96
24
5
6
96
24
5
8
96
24
4
10
96
24
4
12
96
30
4
14
96
36
4
16
96
36
4
18
70,000
HEIGHT
DIA.
DRAIN
VENT
72
24
4
2
72
24
4
2
72
24
4
2 1/2
72
24
4
3
72
24
4
4
72
24
4
5
72
24
4
6
72
24
4
8
72
24
4
10
72
24
4
12
72
30
4
14
72
36
4
16
72
36
4
18
60,000
HEIGHT
DIA.
DRAIN
VENT
56
24
4
2
56
24
4
2
56
24
4
2 1/2
56
24
4
3
56
24
4
4
56
24
4
5
56
24
4
6
56
24
4
8
56
24
4
10
56
24
4
12
56
30
4
14
56
36
4
16
50,000
HEIGHT
DIA.
DRAIN
VENT
72
20
4
2
72
20
4
2
72
20
4
2 1/2
72
20
4
3
72
20
4
4
72
20
4
5
72
20
4
6
72
20
4
8
72
20
4
10
72
24
4
12
72
30
3
14
72
36
3
16
40,000
HEIGHT
DIA.
DRAIN
VENT
56
20
4
2
56
20
4
2
56
20
4
2 1/2
56
20
4
3
56
20
4
4
56
20
4
5
56
20
4
6
56
20
4
8
56
20
3
10
56
24
3
12
56
30
3
14
30,000
HEIGHT
DIA.
DRAIN
VENT
56
18
3
2
56
18
3
2
56
18
3
2 1/2
56
18
3
3
56
18
3
4
56
18
3
5
56
18
3
6
56
18
3
8
56
20
3
10
56
24
2 1/2
12
20,000
HEIGHT
DIA.
DRAIN
VENT
56
14
2 1/2
2
56
14
2 1/2
2
56
14
2 1/2
2 1/2
56
16
2 1/2
3
56
16
2 1/2
4
56
16
2 1/2
5
56
16
2 1/2
6
56
16
2 1/2
8
56
20
2
10

10,000

HEIGHT
DIA.
DRAIN
VENT
34
14
2
2
34
14
2
2
34
14
2
2 1/2
34
14
2
3
34
14
2
4
34
14
2
5
34
14
2
6
56
16
1.5
8
5,000
HEIGHT
DIA.
DRAIN
VENT
34
10
1 1/2
2
34
10
1 1/2
2
34
10
1 1/2
2 1/2
34
10
1 1/2
3
34
14
1 1/2
4
34
14
1 1/2
5
34
14
1 1/2
6
3,000
HEIGHT
DIA.
DRAIN
VENT
34
10
1 1/4
2
34
10
1 1/4
2
34
10
1 1/4
2 1/2
34
10
1 1/4
3
34
14
1 1/4
4
2,000
HEIGHT
DIA.
DRAIN
VENT
34
8
1 1/4
2
34
8
1 1/4
2
34
8
1
2 1/2
34
10
1
3
1,000
HEIGHT
DIA.
DRAIN
VENT
34
6
1
2
34
8
1
2
34
8
1
2 1/2

CHART "B" - SIZING FOR FLASH SEPARATOR

To use Chart B select the Flash Separator by finding the flash amount across the top and going down to the total condensate flow rate entering the separator shown on the left side of the chart.


The drain and vent sizes listed in Chart "B" are based on atmospheric operating conditions. When the flashing to pressure is above atmospheric pressure, smaller drain and vent sizes can be used. The drain size in no case should be smaller then the trap connection size. To determine the minimum vent size use the following formula:

.

Where:
Dia. Equals the minimum diameter of vent (inches)
F The amount of flash steam in lbs./hour
SV Is the specific volume of steam (cu. Ft/lbs.)


PENN SEPARATOR CORPORATION
5 South Pickering
P.O. BOX 340
Brookville, PA 15825
(814) 849-7328
Fax: (814) 849-4510
TOLL FREE: 1-888-PENN-SEP (7366-737)


Designed by OnTech
OnTech